Type
4/3
Nominal voltage/ current type
12 V DC
Overlap
positive (closed)
Please choose a variant
Article
HK DG4V5 0BJ VM U 12DC
HK DG4V5 0B VM U 110AC
HK DG4V5 2A VM U 110AC
HK DG4V5 2ALJ VM U 12DC
HK DG4V5 2AL VM U 110AC
HK DG4V5 2BJ VM U 12DC
HK DG4V5 2BJ VM U 24DC
HK DG4V5 2B VM U 110AC
HK DG4V5 2B VM U 230AC
HK DG4V5 6BJ VM U 12DC
HK DG4V5 6BJ VM U 24DC
HK DG4V5 6B VM U 110AC
HK DG4V5 6B VM U 230AC
HK DG4V5 22AJ VM U 12DC
HK DG4V5 22AJ VM U 24DC
HK DG4V5 22A VM U 110AC
HK DG4V5 22A VM U 230AC
HK DG4V5 0CJ VM U 12DC
HK DG4V5 0C VM U 110AC
HK DG4V5 2C VM U 110AC
HK DG4V5 6CJ VM U 12DC
HK DG4V5 2NJ VM U 12DC
HK DG4V5 2NJ VM U 24DC
HK DG4V5 2N VM U 110AC
HK DG4V5 2N VM U 230AC
Change Point of Service
Register now to get access to our online shop
Register now and access our complete product range and many exclusive services.
Product details for
HK DG4V5 6CJ VM U 12DC
Type
4/3
Nominal voltage/ current type
12 V DC
Overlap
positive (closed)
Piston type
6CJ [PB/AT]-[ABT/P]-[PA/BT]
Design
spring return to 0
All characteristics
Characteristics
Max. working pressure
- P, A, B: max. 315 bar / T: max. 160 bar (V DC) / T: max. 120 bar (V AC)
Design
- 4/2-way valve or 4/3-way valve
- with manual override function
Connection
- ISO/Cetop 05 size 10
Flow rate
- max. 120 l/min (note characteristic curves)
Mounting
- 4 pcs. hexagon socket screw M 6 x 40 12.9
- screw set HK M6 40 for 1 basic valve. In vertical stacking applications with intermediate plates, the use of the appropriate longer screws are required.
Protection class
- IP 65
Customs tariff number
- 84812010
All characteristics
Product description
Notes
Description
Ordering information
Delivery scope
Product variants
25 Results
Search
Show dimensional drawing
Identifier
Price / items
4/2
12 V DC
negative (open)
0BJ [PB/AT]-[ABPT]
4/2
110 V AC
negative (open)
0B [PB/AT]-[ABPT]
4/2
110 V AC
positive (closed)
2A [PB/AT]-[PA/BT]
4/2
12 V DC
positive (closed)
2ALJ [PB/AT]-[PA/BT]
4/2
110 V AC
positive (closed)
2AL [PB/AT]-[PA/BT]
4/2
12 V DC
positive (closed)
2BJ [PB/AT]-[A/B/P/T]
4/2
24 V DC
positive (closed)
2BJ [PB/AT]-[A/B/P/T]
4/2
110 V AC
positive (closed)
2B [PB/AT]-[A/B/P/T]
4/2
230 V AC 50 Hz
positive (closed)
2B [PB/AT]-[A/B/P/T]
4/2
12 V DC
positive (closed)
6BJ [PB/AT]-[ABT/P]
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]
Shows 10 of 25
Column selection
Type
Nominal voltage/ current type
Overlap
Piston type
Design
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]